But, that also means you may have some control over the pump. You will not be able to obtain a pump RPM reading if the pump cable is connected to the power supply via 4 pin Molex to 3 pin fan adapter. New comments cannot be posted and votes cannot be cast, More posts from the overclocking community. I’m a bit of a noob, but from what I understand the coolant pump should be running at 100%. So in my case (where the pump speed was the point of thermal bottleneck) changing the speed saw decent drop in temperatures. If your pump RPM is displaying 0 or N/A then the pump is not functioning. Dive into the creative building experience and see how your rig can be customized for gaming, modding, design, music, and more. the hose that moves coolant from the radiator to the AIO pump block) is on the bottom when you mount them. Cookies help us deliver our Services. I want to make sure … How long did you run with that, and have you delidded? Thanks. When I go into my bios to control the pump and fans, it won’t let me control the pump separately from the cooler … Before that I was using a system header. Example Only: Please use our contact form for any further queries. I like the CPU Fan header more than the AIO header as you are able to control pump speed more granularly. Water cooling systems -- whether they are a custom loop or an AIO-- all follow the same basic principles. I hopped into BIOS and clicked all set default and it went to smart fan mode and changes fan speed depending on the temperature. This is like the manual describes. All things overclocking go here. In the summer my cpu is a few degrees warmer than usual. Cooler Master MasterLiquid ML240 Mirror ARGB Close-Loop AIO CPU Liquid Cooler, Mirror ARGB Pump, 240 Radiator, Dual SickleFlow 120mm, 3rd Gen Dual Chamber Pump for AMD Ryzen/Intel 1200, 1151 4.6 out of 5 stars 349 For example 30 seconds of Prime95 will make your fans go nuts, but realistically might increase the temp in the loop by 0.5c, if that. As long as you have some basic rate of flow going it doesn't much matter how fast the pump is actually set. COOLER MASTER MASTERPLUS (PER. In BIOS you set it to 100% and then let the software manage it in relation to the AIO water temp. Looking at the Cooler Master dual-pump AIO, vapor chamber tower coolers, novec cooling solution, and new air coolers. Therefore I've been managing it in BIOS. Looks like you're using new Reddit on an old browser. Find helpful customer reviews and review ratings for Cooler Master MasterLiquid ML360 Mirror ARGB Close-Loop AIO CPU Liquid Cooler, Mirror ARGB Pump, 360 Radiator, Triple SickleFlow 120mm, 3rd Gen Dual Chamber Pump for AMD Ryzen/Intel LGA1200/1151 at Amazon.com. Therefore, I can't control without being in BIOS. Read honest and unbiased product reviews from our users. If you are enthusiastic gaming or professionals, this cooler will suit your working environment. Entry level AIOs, especially those released a few years ago, just operate off of a PWM (CPU) fan header. To be honest I keep my pumps on the quietest setting and I've never had an issue with the temps or thermal throttling. Join us. To a point once over that point it makes very little difference . You have the reservoir, the pump, the radiator, the fans, some tubing, a … Different ppl have different views . I didn’t see any software or anything, and the Asus software that came with my mobo that I use to control my fans can see the pump, but shows it sitting at 2400rpm with no way to change it. You want their activity tied to that, not cpu temp. 1.415v seems fairly ballsy. The Pump is connected to AIO_PUMP socket socket. DESCRIPTION Supported Products: - Headset : MH752, MH670, MH650 - MousePad : MP860, MP750 With an AIO you should have a usb connection to let it be managed by software? You can just leave the pump at 50%. In fact, the Cooler Master brand is famous for its noise controlling level. The pump is a 3 pin. Fan Speed 650-2000 RPM (PWM) ± 10% Fan Airflow 66.7 CFM (Max) Fan Air Pressure 2.34 mmH2O (Max) Fan MTTF 160,000 Hours Fan Power Connector 4-Pin (PWM) Fan Rated Voltage 12VDC Pump Dimensions 83.6 x 71.8 x 52.7 mm / 3.3 x 2.8 x 2.1 inch Pump MTTF 70,000 Hours Pump Noise Level < 15 dBA Pump Connector 3-Pin Pump Rated Voltage 12 VDC Warranty 2 years Cooler Type Liquid Cooler My two 120mm fans on my radiator cranked up big time after the switch. Hi guys. The fans are supposed to be connected to the CPU fan header so that their speed … Please submit an RMA through CM Fanzone for a replacement. My CoolerMaster ML360R AIO liquid cooler is noisy when running at 2200-2400 rpm. If you have a smaller itx case, or poor airflow. The site may not work properly if you don't, If you do not update your browser, we suggest you visit, Press J to jump to the feed. Is there other software that I could use? First, you will need to check which fan header the pump cable is connected to on the motherboard. Values after I start CAM once and I do not cut the power from PSU BIOS show 5500+ rpm while the max speed of the pump is ~2.700 rpm HWInfo shows ~2.700 rpm The only way really to find what works best is to do some testing , with a stress test program and temp monitoring programs . Learn to overclock, ask experienced users your questions, boast your rock-stable, sky-high OC and help others! I also read somewhere online that it's best to keep it at a constant rate; therefore, 100 is fine because I wouldn't have to worry about it not cooling enough and adjusting it, disrupting the flow. Across the board, this adjusts fan speeds. As for pump speed, again this would be controlled by software, rather than using the pump header on your motherboard. All the AIO's software usually allows you to select a Silent/Quiet mode or a Performance mode. This will only be possible if the pump cable is connected directly to a fan header on the motherboard. As mentioned earlier, the ML240L V2 RGB is equipped with the latest 3rd generation dual-chamber pump by Cooler Master. The motherboard documentation says to plug the pump into CPU OPT and the fans into CPU. And I leave my fans at 1500rpm. Please Note: Cooler Master recommends contacting the motherboard manufacture if you are not familiar with navigating BIOS. At default it's under smart fan so the radiator fan speeds goes up and down. Corsair Link, that sort of thing. But it’s still way under 50c during gaming. The World of PC Building. Because the noise level of the cooler is 31.5dB. Please submit an RMA through CM Fanzone for a replacement. This will help you to identify the correct RPM reading. When I had my 7700k OC'd to 5 GHz @ 1.415 V on a 240 AIO with 3000 rpm fans at max; changing the pump from ~1800 RPM to ~2700 RPM dropped my temps around 5-7°C. The pump should be connected to a non-CPU fan header because it was designed to run at full speed. I'll tryout different pump speeds and see how it goes. Is it at a constant rate? Dreadful advice. You absolutely don’t want the fans changing speed based on BIOS pwm as that has absolutely no relation to the temperature of the water in the radiators. Press question mark to learn the rest of the keyboard shortcuts. You’ll just get fans that are changing speed all over the place for absolutely no reason. It looks really similar to the pump on the previous ML240L RGB at first glance, but you can immediately notice the difference in height between both pumps if it’s compared side by side – the ML240L V2 RGB pump is visibly taller than the ML240L RGB. Would the setting in BIOS be the same? Hi everyone, I have a cooler master ML240 liquid cooler, paired to a Gigabyte Aorus B450M motherboard. Just make sure that the "return hose" (i.e. item 3 Thermaltake Pacific DIY LCS PR22-D5 300ml 5-Speed Adjustable D5 Pump/Reservoi ... Cooler Master MasterLiquid ML240L V2 RGB 240mm AiO Liquid CPU Cooler. When I had my 7700k OC'd to 5 GHz @ 1.415 V on a 240 AIO with 3000 rpm fans at max; changing the pump from ~1800 RPM to ~2700 RPM dropped my temps around 5-7°C. However, now my idle temp went up 5-10 degrees. It’s not cooling the cpu it’s cooling the water in the loop. Cooler Master Corp (CMC) with original design & in-house manufacturing capabilities. Cooler Master 120mm AIO cooler never lets you down by its performance. Works great. Thanks for the info! Seems to only run at 3.9 and lower for some reason. If that. On performance the pump sits around 3,000rpm. I am using an AIO Lepa Aquachanger 240. Next, you can check the pump RPM via BIOS or in Windows by downloading HW Monitor (free program) If your pump RPM is displaying 0 or N/A then the pump is not functioning. So just experiment with it, 100 is fine, and a lot less pumping is also fine. After OCing my CPU, I can't get msi command center to run anymore. I've never noticed a noticeable difference of the difference between temps of max too. Given that AIO is only going to be using a single waterblock your loop resistance is probably fairly low. I just rename CPU Fan to PUMP in Fan Expert. The difference 50% and 100% pump speed is probably 2-3c on the cpu. Cooler Master MasterLiquid ML360R ARGB Close-Loop AIO CPU Liquid Cooler, 360 Radiator, Dual Chamber Pump, Addressable RGB Lighting, Dual MF120R Fans for AMD Ryzen/Intel LGA1200/1151 Extra savings w/ promo code FEBPCSAVE28, limited offer Like it’s supposed to be. You want the fans to ramp up when the water needs cooling not when the CPU does.